ER300
EMI TEST RECEIVER
Features
. Frequency range: 1kHz—300MHz/2GHz/3.6GHz
. Multiple digital detection functions, includingCISPR-AVG、CISPR-RMS、QPK
. Multiple EMI measurement standards
. Optimal sensitivity - 145dBm
. Resolution bandwidth 1Hz~3MHz(-3dB), 200Hz/9kHz/120kHz/1MHz(-6dB)
. Plenty of measurement options available
. Double RF input protection ensures measurement safety
. Support ETR measurement analysis software
. 8.4-inch high-brightness TFT LCD display
. Universal USB and LAN for convenient control
. The weight does not exceed 6.5kg
Spectrum analysis mode | |||
Frequency range | ER300 | 1kHz~300MHz | |
ER2000 | 1kHz~2GHz | ||
ER3600 | 1kHz~3.6GHz | ||
Reading accuracy | ±(frequency indication x frequency accuracy+1%span+10%RBW+0.5x[span/(sweep dot-1)]+1Hz) | ||
Internal time base (10MHz) | Aging rate | 1ppm/year | |
Temperature drift | <0.5ppm(15℃~35℃) | ||
SSB phase noise (f=500MHz) | |||
Offset 30kHz | -90dBc/Hz | ||
Offset 1MHz | -110dBc/Hz | ||
Amplitude | |||
Maximum input level | Average continuous power | +36dBm | |
Max. DC Input voltage | 50Vdc | ||
Display average noise level | |||
Channel | Frequency | Preamp off | Preamp on |
Frequency conversion channel | 100kHz~1MHz | ≤-100dBm-30*(f/100kHz)dB | ≤-120dBm-30*(f/100kHz)dB |
1MHz ~ 10MHz | ≤-130dBm | ≤-150dBm | |
10MHz ~ 1GHz | ≤-135dBm | ≤-155dBm | |
1GHz ~ 3.6GHz | ≤-140dBm | ≤-148dBm | |
Low frequency channel | 5kHz~10kHz | ≤-110dBm | |
10kHz~10MHz | ≤-125dBm | ||
Uncertainty ofamplitude measurement(20℃~30℃) | |||
Combined amplitude Accuracy(90%) | ±1.8dB | ||
Resolution bandwidth(-3dB) | |||
Resolution bandwidth range | 1Hz~3MHz,steps | ||
Uncertainty ofresolution bandwidth conversion | 1Hz≤RBW≤500kHz | ±0.6dB | |
RBW>500kHz | ±1.0dB | ||
Resolution bandwidth accurate | <10% | ||
Attenuator | |||
Attenuation range | 0~39dB,3dBsteps | ||
Attenuatoruncertainty | ±1.0dB | ||
Residual response | |||
≤ -96dBm | |||
Frequency response | |||
5kHz~200kHz | ±1.8dB | ||
200kHz~3.6GHz | ±1.5dB | ||
Detector | |||
Auto、normal 、+peak、-peak、sampling | |||
Sweep time | |||
Conversion channel | Span = 0 | 1ms~3000s | |
Span > 0 | 3ms~3000s | ||
Input port SWR | |||
50MHz~1GHz | ≤ 2.0 | ||
EMI receiving mode | |||
Frequency range | ER300 | 1kHz~300MHz | |
ER2000 | 1kHz~2GHz | ||
ER3600 | 1kHz~3.6GHz | ||
Reading accuracy | ±(frequency indication x frequency accuracy + 0.5 display unit) | ||
Uncertainty of amplitude measurement(20℃~30℃) | Combined amplitude accuracy(90%) | ±2.0dB | |
Resolution bandwidth (-6dB) | Resolution bandwidth range | 200Hz/9kHz/120kHz/1MHz | |
uncertainty ofresolution bandwidth | <10% | ||
Detector | +peak、-peak、qoasi peak、average、RMS | ||
Sweep time | 100us~100s | ||
Sweep point | 101~1001 | ||
Trace number | 3(parallel detection) | ||
Frequency band list | 10 | ||
Frequency response | ±2.0dB | ||
Tracing source | |||
Frequency range | 10kHz~1.5GHz | ||
Output power | -30dBm~0dBm | ||
Output flatness | ±3dB | ||
Common parameter | |||
Display | 8.4”TFT-LCD | ||
Resolution | 800×600 | ||
Communication interface | LAN、USB | ||
Operating temperature | 0℃~40℃ | ||
Storage temperature | -30℃~+70℃ | ||
Weight | 7.5kg | ||
Dimensions (l * w * h) | 400mm×280mm×190mm |